Skip to main navigation Skip to main content Skip to page footer

TRAXLINE® PROFIBUS 700 CD

Double-shielded continuous bending hi-flex Profibus PUR cables

1

PUR outer jacket

<p>pressure-extruded, hi-flex design, high abrasion resistant</p>

2

CU braided cover

<p>tinned with high flexibility</p>

3

Foil-shield

<p>Metal lamination very high shield efficiency</p>

4

TPE inner jacket

<p>valley-sealed-extruded, hi-flex design</p>

5

Twisted pair stranding

<p>for safe data transmission</p>

Up to 7 Million
Motion cycles

Up to 100 m
Travel length

General information

  • For Process Field Bus applications
  • Pair twisted cores reducing common mode intefereces
  • Good EMC-protection by double overall-shield
  • Outer jacket pressure extruded and high abrasion resistant
  • Inner jacket valley-sealed extruded

Norms and standards

  • Oil-resistant
  • REACH/RoHS II
  • UV-resistant
  • Flame-retardant
  • Ozone-resistant
  • NEK 606
  • Silicone-free
  • Halogen-free
  • CFC-free

Design

Conductor:Class 6
Core insulation:PE/02Y Foam
Core identification:Red, green
Core stranding:Cores pair twisted in short pitches with minimal torsion
Inner jacket:PP/TPE
Shield:Double shielded
Jacket color:Violet
Outer jacket:PUR

Technical data

Temperature range while moved:-40 up to +70 °C
Minimum bend radius while moved:KRmin ≥ 15 x Ø
Vmax supported:3.5 m/s
Vmax gliding:2 m/s
amax supported:10 m/s2
amax gliding:10 m/s2
Insulation resistance:> 10 MΩ x km
Nominal voltage control core(s):according to VDE 0.30 kVV
according to UL 0.30 kV

Varying parameters possible.

Type selection

TRAXLINE® PROFIBUS 700 CD – Double-shielded

Core number x Cross-section
[mm2]

Part no.

max. ∅
[mm]

Cable weight
[kg/m]

Copper index
[kg/m]

Datasheet

((1 x 2 x 0.64))

45690

8.4

0.070

0.025

View

Additional types upon request.