United States
Call: 800.323.7790 | |  

LE60 RE

Plastic stay RE – frame screw-in stay

LE60 RE Start
L60 RE Stay variants
Properties
  • Plastic profile bars for light to medium loads. Assembly without screws.
  • Outside/inside: release by rotating.
Stay arrangement on every chain link

Stays mounted on each chain link (VS: fully-stayed)

Inner width
Bi 85 – 250 mm
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
Bi
[mm]
Bk
[mm]
qk
[kg/m]
60 88 85 125 138 150 180 196 225 250 Bi + 28 3.00 – 4.20
KR
[mm]
135150175200250300350400500

Order example

Order code

LE 60

180

RE

250

2184

VS

Inner distribution

Divider systems

The divider system is mounted on every 2nd chain link as a standard.
As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (Version A).

Divider system TS0

without height separation
LE60 RE TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A10139

The dividers can be moved in the cross section.

Divider system TS1

with continuous height separation
LE60 RE TS1 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A101392

The dividers can be moved in the cross section.

Divider system TS3

with height separation consisting of plastic partitions

As a standard, the divider version A is used for vertical partitioning within the cable carrier. The complete divider system can be moved within the cross section.

Divider version A

LE60 RE TS3 Version A

End divider

LE60 RE TS3 Version B
LE60 RE TS3 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A8 / 4*14102

* for End divider

The dividers are fixed by the partitions, the complete divider system is movable in the cross section.

Partitions (2.5) EN
ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
14
10
16
12
19
15
23
19
24
20
28
24
29
25
32
28
33
29
34
30
38
34
39
35
43
39
44
40
48
44
49
45
54
50
58
54
59
55
64
60
68
64
69
65
74
70
78
74
79
75
80
76
84
80
88
84
89
85
94
90
96
92
99
95
112
108

An additional central support is required when using plastic partitions with ax > 49 mm.

Order example

Order code

TS3

A

3

K1

K4

34

38

VR1

VR3

Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).

If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

Universal end connectors UMB – plastic (standard)

The universal mounting brackets (UMB) are made from plastic and can be mounted from the top, from the bottom or face on.

L60 Universal end connectors UMB – plastic (standard)
L60 Universal end connectors UMB – plastic (standard)
L60 Universal end connectors UMB – plastic (standard)
Connection point

F – fixed point
M – driver

Connection type

U – universal mounting bracket

Order example

Order code

UMB

F

U

UMB

M

U

End connector

UMB

UMB

Connection point

F

M

Connection type

U

U

Important information

We recommend the use of strain reliefs before driver and fixed point.

Subject to change.
^