Plastic stay RD 02 – frame stay with hinge in the outer radius

MK0475 RD 2 Start
M0475 02 Stay variants
Properties
  • Plastic profile bars with hinge for light to medium loads.
    Assembly without screws.
  • Available customized in 8 mm grid.
  • Outside: swivable to both sides.
  • Inside: release by turning by 90°.
Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width (B<sub>i</sub>) in 8 mm increments
Bi 24 – 280 mm in 8 mm width sections
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
Bi
[mm]
Bk
[mm]
qk
[kg/m]
28 39 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136 144 152 160 168 176 184 192 200 208 216 224 232 240 248 256 264 272 280 Bi + 17 0.79 – 3.03
* in 8 mm width sections
KR
[mm]
5575100130160200250300

Order example

Order code

MK0475

128

RD 2

100

1425

VS

Inner distribution

Divider systems

As a standard, the divider system is mounted on each crossbar – for stay mounting on every 2nd chain link (HS).
As a standard, dividers and the complete divider system (dividers with height separations) can be moved in the cross section (version A).

The dividers are easily attached to the stay for applications with lateral acceleration and for applications laying on their side by simply turning the frame stay by 180°. The arresting cams click into place in the locking grids in the crossbars (Version B). The groove in the frame stay faces outwards.

Divider system TS0

without height separation
MK0475 RD 2 TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A67.85
B1285.28

The dividers can be moved within the cross section (version A) or fixed (version B).

Divider system TS1

with continuous height separation
MK0475 RD 2 TS1 EN
Vers.
aT min
[mm]
aT max
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A6207.852
B122085.282

The dividers can be moved within the cross section (version A) or fixed (version B).

Divider system TS2

with partial height separation
MK0475 RD 2 TS2 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
B128*/245.2*/21.282

* for VR0

With grid distribution (8 mm grid). The dividers are fixed by the height separation, the complete divider system is movable in the cross section (version A) or fixed (version B).

Order example

Order code

TS2

A

3

K1

K4

34

38

VR1

VR3

End connectors

End connectors – plastic/steel (with strain relief)

Link end connector made of plastic, end connector made of sheet steel with screw-fixed aluminum strain relief. The connection variants on the fixed point and on the driver can be combined and, if required, changed afterwards.

M0475 End connectors – plastic/steel (with strain relief)
M0475 End connectors – plastic/steel (with strain relief)
Bi
[mm]
X
[mm]
nz
40
17.5 3
56
21.5 4
80
17.5 6
104
19 8
128
19.5 9
152
17.5 11
192
18.5 14
M0475 End connectors – plastic/steel (with strain relief)
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside

Connection surface

I – connection surface inside

Order example

Order code

Plastic/steel

F

A

I

Plastic/steel

M

A

I

End connector

Plastic/steel

Plastic/steel

Connection point

F

M

Connection type

A

A

Connection surface

I

I

End connectors – plastic/steel

Plastic link end connector, steel end connector. The connection variants on the fixed point and on the driver can be combined and, if required, changed afterwards.

M0475 End connectors – plastic/steel
M0475 End connectors – plastic/steel
M0475 End connectors – plastic/steelM0475 End connectors – plastic/steel
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside
F – flange connection

Connection surface

I – connection surface inside
A – connection surface outside

Order example

Order code

Plastic/steel

F

A

A

Plastic/steel

M

U

 

End connector

Plastic/steel

Plastic/steel

Connection point

F

M

Connection type

A

U

Connection surface

A

Important information

We recommend the use of strain reliefs before driver and fixed point.

Subject to change.
^