United States
Call: 800.323.7790 | |  

KE0650 RE

Plastic stay RE – screw-in frame stay

KE0650 RE Start
K0650 RE Stay variants
Properties
  • Plastic profile bars for light and medium loads. Assembly without screws.
  • Available customized in 8 mm grid.
  • Outside/inside: to open by rotating 90°.
Stay arrangement on every 2<sup>nd</sup> chain link

Stay arrangement on every 2nd chain link, standard (HS: half-stayed)

Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width (B<sub>i</sub>) in 8 mm increments
Bi 68 – 260 mm in 8 mm width sections
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
Bi
[mm]
Bk
[mm]
BEF
[mm]
qk
[kg/m]
42 57.5 68 76 84 92 100 108 116 124 132 140 148 156 164 172 180 188 196 204 212 220 228 236 244 252 260 Bi + 28 Bi + 36 1.75 – 2.71
* in 8 mm width sections
KR
[mm]
75115145175220300

Order example

Order code

KE0650

140

RE

115

2600

HS

Our technical support can provide help for gliding arrangements: engineeringsupport@kabelschlepp.com

Inner distribution

Divider systems

The divider system is mounted on each crossbar as a standard – on every 2nd chain link for stay mounting (HS – half-stayed).
As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).

For applications with lateral accelerations and applications with the cable carrier rotated by 90°, the dividers can easily be fixed by turning the frame stay by 180°. The arresting cams click into place in the locking grids in the crossbar (version B). The groove in the frame stay faces outwards.

Divider system TS0

without height separation
KE0650 RE TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A6.5138.82
B131611.882

The dividers can be moved in the cross section.

Divider system TS1

with continuous height separation
KE0650 RE TS1 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A6.5138.82

The dividers can be moved in the cross section.

Divider system TS3

with height separation consisting of plastic partitions
KE0650 RE TS3 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A416 / 42*82

* for aluminum partitions

The dividers are fixed with the partitions. The entire divider system can be moved in the cross section.

Partitions Base

Aluminum partitions with 1 mm increments with ax > 42 mm are also available.

ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
16
8
18
10
23
15
28
20
32
24
33
25
38
30
43
35
48
40
58
50
64
56
68
60
78
70
80
72
88
80
96
88
112
104
128
120
144
136
160
152
176
168
192
184
208
200

When using plastic partitions with ax > 112 mm, we recommend an additional center support with a twin divider (ST = 4 mm). Twin dividers are also suitable for retrofitting in the partition system.

Order example

Order code

TS3

A

3

K1

K4

34

38

VR1

VR3

Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).

If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

Universal end connectors UMB – plastic (standard)

The universal mounting brackets (UMB) are made from plastic and can be mounted from the top, from the bottom or face on.

K0650 Universal end connectors UMB – plastic
K0650 Universal end connectors UMB – plastic
K0650 Universal end connectors UMB – plastic
Connection point

F – fixed point
M – driver

Connection type

U – universal mounting bracket

Order example

Order code

UMB

F

U

UMB

M

U

End connector

UMB

UMB

Connection point

F

M

Connection type

U

U

Important information

We recommend the use of strain reliefs before driver and fixed point.

Subject to change.
^