Stay variant 080 – covered on both sides with outside detachable cover

TKA55 080 Stay variants

Properties

  • Plastic cover for rough environmental conditions with dirt, chips or spray water.
  • Fully detachable on one side in any position.
  • Outside: very quick release.
Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width
Bi 50 – 150 mm

Dimensions

Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
Dimensions
hi
[mm]
hG
[mm]
Bi
[mm]
Bk
[mm]
qk
[kg/m]
45 65 50 75 100 125 150 175 200 225 250 Bi + 20 1.95 – 4.28
KR
[mm]
100120140170195225250300

Order example

Order code

TKA55

080

200

225

2553

VS

Our technical support can provide help for gliding arrangements: engineeringsupport@kabelschlepp.com

Inner distribution

Divider systems

The divider system is mounted on every 2nd chain link as a standard. As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (Version A).

The dividers are easily attached to the stay for applications with transverse accelerations and for applications laying on the side by simply turning them.
The locking cams click into place in the locking grids in the covers (Version B).

Divider system TS0 without height separation
TKA55 TS0
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A5107
B1072
Bi [mm]
aT min [mm]
50
13
75
11.5
100
12
125
12.5
150
13
175
11.5
200
12
225
12.5
250
13
Divider system TS1 with continuous height separation
TKA55 TS1
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A51072
B10722
Bi [mm]
aT min [mm]
50
13
75
11.5
100
12
125
12.5
150
13
175
11.5
200
12
225
12.5
250
13
Divider system TS3with height separation consisting of plastic partitions

As a standard. the divider A is used for vertical ­partitioning within the cable carrier. The complete divider system can be moved within the cross section. (version A).

The dividers are easily attached to the stay for applications with transverse accelerations and for applications laying on the side by simply turning them. 
The locking cams click into place in the locking grids in the covers (version B).

Divider version A

TKA55 TS3 Divider Version A

End divider

TKA55 TS3 End Divider
TKA55 TS3
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A4/2*14102

* for End divider

The dividers are fixed by the partitions, the complete divider system is movable in the cross section.

Partitions (2.5)
ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
14
10
16
12
19
15
23
19
24
20
28
24
29
25
32
28
33
29
34
30
38
34
39
35
43
39
44
40
48
44
49
45
54
50
58
54
59
55
64
60
68
64
69
65
74
70
78
74
79
75
80
76
84
80
88
84
89
85
94
90
96
92
99
95
112
108

When using partitions with ax > 49 mm we recommended an additional preferential central support. 

Order example

Order code

TS1

A

3

VD0

VD1

Please state the designation of the divider system (TS0, TS1 …), version and number of dividers per cross section [nT].

If using divider systems with height separation (TS1), please also state the positions [e.g. VD1] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

Universal end connectors UMB – plastic (standard)

The universal end connectors (UMB) are made from plastic and can be mounted from the top, from the bottom, or face on.

Important information

Recommended tightening torque:
5 Nm for cheese-head screws ISO 4762 - M5 x 8.8

Bi
[mm]
BEF
[mm]
nz
50
74 2 x 3
75
99 2 x 5
100
124 2 x 7
125
149 2 x 9
150
174 2 x 11
175
199 2 x 13
200
224 -
225
249 -
250
274 -

The end connectors are also available as an option without cover sheets. Please state when ordering.

Connection point

F – fixed point
M – driver

Connection type

U – universal end connector

Order example

Order code

UMB

F

U

UMB

M

U

End connector

UMB

UMB

Connection point

F

M

Connection type

U

U