Aluminum stay RM –  frame stay, solid

S/SX1250 RM Start
S/SX1250 RM Stay variants
Properties
  • Aluminum profile bars for heavy loads and maximum cable carrier widths. Double threaded joint on both sides “Heavy Duty”.
  • Available customized in 1 mm grid.
  • Inside/outside: Threaded joints easy to release.
HeavyDuty
Stay arrangement on every 2<sup>nd</sup> chain link

Stay arrangement on every 2nd chain link, standard (HS: half-stayed)

Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width (B<sub>i</sub>) in 1 mm increments
Bk 200 – 800 mm in 1 mm width sections
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
hG'
[mm]
Bi
[mm]
BSt
[mm] *
Bk
[mm]
BEF
[mm]
qk
[kg/m]
69 94 104 151 – 751 176 – 776 BSt + 24 BSt + 30 13.42 – 17.01
* in 1 mm width sections
KR
[mm]
1452002202603003403804204605005406001000

Order example

Order code

S1250

400

RM

200

St

4750

HS

Our technical support can provide help for gliding arrangements: engineeringsupport@kabelschlepp.com

Inner distribution

Divider systems

The divider system is mounted on each crossbar as a standard – on every 2nd chain link for stay mounting (HS – half-stayed).
As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).

Divider system TS0

without height separation
S/SX1250 RM TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A17.52015

The dividers can be moved in the cross section.

Divider system TS1

with continuous height separation
S/SX1250 RM TS1 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A101282

The dividers can be moved in the cross section.

Divider system TS2

with partial height separation
S/SX1250 RM TS2 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A1721152

With grid distribution (1 mm grid). The dividers are attached by the height separation, the grid can be moved in the cross section.

Sliding dividers are optionally available (thickness of divider = 4 mm).

Order example

Order code

TS1

A

3

K1

K4

34

38

VR1

VR3

End connectors

End connectors – steel

End connectors made of steel. The connection variants on the fixed point and on the driver can be combined and changed later on, if necessary.

S/SX1250 End Connector
S/SX1250 End Connector
S/SX1250 End Connector
S/SX1250 End Connector
S/SX1250 End Connector
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint to outside (standard)
I – threaded joint to inside
H – threaded joint, rotated 90° to the outside
K – threaded joint, rotated 90° to the inside

Connection surface

I – connection surface inside
A – connection surface outside

Important information

Caution: The standard connection variant FAI/MAI is only possible from Bk of 125 mm.

Order example

Order code

Steel

F

A

I

Steel

M

A

I

End connector

Steel

Steel

Connection point

F

M

Connection type

A

A

Connection surface

I

I

Important information

We recommend the use of strain reliefs before driver and fixed point.

Subject to change.
^