United States
Call: 800.323.7790 | |  

LS/LSX1050 RS 2

Aluminum stay RS 2 – Frame stay narrow, threaded joint

LS/LSX1050 RS 2 Start
LS/LSX1050 RS 2 Stay variants
Properties
  • Quick to open and close
  • Aluminum profile bars for light to medium loads. Simple threaded joint.
  • Available customized in 1 mm grid.
  • Inside/outside: Threaded joint easy to release.
Stay arrangement on every 2<sup>nd</sup> chain link

Stay arrangement on every 2nd chain link, standard (HS: half-stayed)

Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width (B<sub>i</sub>) in 1 mm increments
Bk 100 – 400 mm in 1 mm width sections
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
Bi
[mm]
BSt
[mm] *
Bk
[mm]
qk
[kg/m]
58 80 184 – 384 84 – 384 BSt + 16 3.63 – 4.11
* in 1 mm width sections
KR
[mm]
105125155195260295325365430

Order example

Order code

LS1050

180

RS 2

125

Sb

2415

HS

Inner distribution

Divider systems

The divider system is mounted on every 2nd chain link as a standard. As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).

For applications with lateral acceleration and rotated by 90°, the dividers can be attached by simply clipping on a socket (available as an accessory).
This socket additionally acts as a spacer between the dividers and is available in a 1 mm grid between 3 – 50 mm, as well as 16.5 and 21.5 mm (Version B).

Divider system TS0

without height separation
LS/LSX1050 RS 2 TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A71410

The dividers can be moved in the cross section.

Divider system TS1

with continuous height separation
LS/LSX1050 RS 2 TS1 EN
Vers.
aT min
[mm]
aT max
[mm]
ax min
[mm]
ac min
[mm]
nT min
A72514102

The dividers can be moved in the cross section.

Divider system TS2

with partial height separation
LS/LSX1050 RS 2 TS2 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A723192

With grid distribution (1 mm grid). The dividers are attached by the height separation, the grid can be moved in the cross section.

Sliding dividers are optionally available (thickness of divider = 4 mm)

Important information

Please note that the real dimensions may deviate slightly from the values indicated here.

Divider system TS3

with height separation consisting of plastic partitions

As a standard, the divider version A is used for vertical partitioning within the cable carrier. The complete divider system can be moved within the cross section.

Divider Version A

LS/LSX1050 RS 2 TS3 Divider Version A

End divider

LS/LSX1050 RS 2 TS3 End divider
LS/LSX1050 RS 2 TS3
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A6/2*14102

* for End divider

The dividers are fixed with the partitions. The entire divider system can be moved in the cross section.

Partitions (2.5) EN
ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
16
8
18
10
23
15
28
20
32
24
33
25
38
30
43
35
48
40
58
50
64
56
68
60
78
70
80
72
88
80
96
88
112
104
128
120
144
136
160
152
176
168
192
184
208
200

When using partitions with ax > 49 mm we recommended an additional preferential central support. 

Order example

Order code

TS3

A

3

K1

K4

34

38

VR1

VR3

Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).

If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

End connectors – steel

End connectors made of steel. The connection variants on the fixed point and on the driver can be combined and, if required, changed afterwards.

LS/LSX1050 End connectors – steel
LS/LSX1050 End connectors – steel
LS/LSX1050 End connectors – steel
LS/LSX1050 End connectors – steel
LS/LSX1050 End connectors – steel
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside

Connection surface

I – connection surface inside
A – connection surface outside

Order example

Order code

Steel

F

A

I

Steel

M

A

I

End connector

Steel

Steel

Connection point

F

M

Connection type

A

A

Connection surface

I

I

Important information

We recommend the use of strain reliefs before driver and fixed point.

Subject to change.
^