United States
Call: 800.323.7790 | |  

UA1320.020

Stay variant 020 – closed frame

UA1320.020 Start
UA1320 020 Stay variants
Properties
  • Weight-optimised, closed plastic frame with particularly high torsional rigidity.
  • Outside/inside: not openable.
Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width
Bi 15 – 65 mm
All pictographs

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
hi
[mm]
hG
[mm]
Bi
[mm]
Bk
[mm]
qk
[kg/m]
20 25.5 15 25 38 50 65 Bi + 12 0.36 – 0.48
KR
[mm]
28384875100

Order example

Order code

UA1320

020

50

100

960

VS

Inner distribution

Divider systems

The divider system is mounted on every 2nd chain link as a standard. As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).

Divider system TS0

without height separation
UA1320.020 TS0 EN
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A486

The dividers can be moved in the cross section.

Divider system TS1

with continuous height separation
UA1320.020 TS1 EN
Vers.
aT min
[mm]
aT max
[mm]
ax min
[mm]
ac min
[mm]
nT min
A420862

The dividers can be moved in the cross section.

Order example

Order code

TS1

A

3

VD0

VD1

Please state the designation of the divider system (TS0, TS1 …), version and number of dividers per cross section [nT].

If using divider systems with height separation (TS1), please also state the positions [e.g. VD1] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

Single-part end connectors – plastic (with integrated strain relief)

The plastic end connectors can be connected from above or below. The connection type can be changed by altering the position of the end connector.

UA1320 End Connector
UA1320 End Connector
UA1320 End Connector
UA1320 End Connector
Bi
[mm]
BEF
[mm]
nz
15
27 2
25
37 3
38
50 4
50
62 5
65
77 6
UA1320 End Connector

The end connectors are also available as an option without integrated strain relief. Please state when ordering.

UA1320 End Connector
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint, rotated 90° to the outside
K – threaded joint, rotated 90° to the inside

Order example

Order code

End connector

F

A

End connector

M

A

End connector

End connector

End connector

Connection point

F

M

Connection type

A

A

Subject to change.
^